Page 45 - BORIN LINE Catalogue 2025 EN
P. 45

Dropping line
                               for wall-mounted                                   Dropping line
                               washing station                                    for washing station
                                                                                   on column














                              Back pipe line






                                                                   Dropping line














          Multiflow system

          operation




          The Multiflow system consists of:

          1.  PRESSURIZATION UNIT
              Located in a technical room, the unit is sized
              according to water demand, meaning the number
              of operators using the system simultaneously. On
              average, each operator requires approximately
              25 L/min of water for effective cleaning. The
              unit includes a mixing tank to ensure a constant
              temperature and oversized pumps powered by
              Brushless motors controlled by inverters, optimizing
              energy consumption and ensuring maximum system
              reliability.
          2.  DISTRIBUTION SYSTEM
              Water is distributed through a main pipeline,
              typically installed in the ceiling area, which connects
              the various dropping lines for washing stations
              across different sections of the facility.